1. Acheteur
1.1.
Acheteur
Nom officiel: University of Helsinki
Forme juridique de l’acheteur: Organisme de droit public
Activité du pouvoir adjudicateur: Enseignement
2. Procédure
2.1.
Procédure
Titre: AVITI24 instrument
Description: The DNA sequencing and genomics laboratory is planning to replace its mid output sequencing instrument. The AVITI24 System is the only instrument in the market that has all the features that are required for the needed sequencing service.
Identifiant de la procédure: ad525420-d46d-4309-906e-958b46aad9c1
Identifiant interne: 556181
Type de procédure: Négociée sans mise en concurrence préalable
2.1.1.
Objet
Nature du marché: Fournitures
Nomenclature principale (cpv): 38000000 Équipements de laboratoire, d'optique et de précision (excepté les lunettes)
2.1.2.
Lieu d’exécution
Subdivision pays (NUTS): Helsinki-Uusimaa (FI1B1)
Pays: Finlande
2.1.4.
Informations générales
Base juridique:
Directive 2014/24/UE
5. Lot
5.1.
Lot: LOT-0000
Titre: AVITI24 instrument
Description: The DNA sequencing and genomics laboratory is planning to replace its mid output sequencing instrument. The AVITI24 System is the only instrument in the market that has all the features that are required for the needed sequencing service.
Identifiant interne: 556181
5.1.1.
Objet
Nature du marché: Fournitures
Nomenclature principale (cpv): 38000000 Équipements de laboratoire, d'optique et de précision (excepté les lunettes)
5.1.2.
Lieu d’exécution
Subdivision pays (NUTS): Helsinki-Uusimaa (FI1B1)
Pays: Finlande
5.1.3.
Durée estimée
Autre durée: Illimité
5.1.6.
Informations générales
Projet de passation de marché non financé par des fonds de l’UE
Le marché relève de l’accord sur les marchés publics (AMP): oui
5.1.10.
Critères d’attribution
Critère:
Type: Prix
Description: price
Catégorie du critère d’attribution poids: Ordre d’importance
Nombre critère d’attribution: 1,00
Justification de l’absence d’indication de la pondération des critères d’attribution: direct procurement
5.1.15.
Techniques
Accord-cadre: Pas d’accord-cadre
Informations sur le système d’acquisition dynamique: Pas de système d’acquisition dynamique
5.1.16.
Informations complémentaires, médiation et réexamen
Organisation chargée des procédures de recours: Markkinaoikeus
TED eSender: Hansel Oy (Hilma)
6. Résultats
Valeur de tous les contrats attribués dans cet avis: 371 100,00 USD
Attribution directe:
Justification de l’attribution directe: Le marché ne peut être exécuté que par un opérateur économique particulier en raison d’une absence de concurrence pour des raisons techniques
Autre justification: Justification for the direct purchase. The justification must be based on one of the preconditions mentioned in the procurement act (1397/2016). ( 40§, 41§, 110§, 119§). 40§ 2) only a certain supplier can implement the procurement for a technical reason, or for a reason related to protecting an exclusive right; it shall be a further condition that there are no reasonable alternatives or substitute solutions, and that the absence of competition is not due to an artificial narrowing of the terms and conditions of the procurement. The DNA sequencing and genomics laboratory is planning to replace its mid output sequencing instrument. Requirements for the new instrument are: • The range of outputs are flexible with low, medium and high throughput kits. • Sequencing cycle outputs are flexible including 150, 300 and 600 cycle kits. • Range of outputs must be flexible (50Gb-600Gb+). • Long size inserts (up-to
1. 5kbp) must be allowed to be used. • Instrument must have two independent flow cells to allow its use in parallel or independently like two sequencers in one. • Linear libraries must be able to be loaded to the flow cell and the library circulation and RCA be made onboard. • It must have sequencing accuracy of very high quality (average Q30 >90%). • Instrument must use rolling circle amplification (RCA) that minimizes common amplification errors: no PCR error propagation, negligible index hopping, low duplicate rates, low AT/GC bias and no optical duplicates. • Instrument must be able to be handle protein and cell capture using the same apparatus and similar slides. The AVITI24 System is the only instrument in the market that has all the features that are required for the needed sequencing service.
6.1.
Résultat – Identifiants des lots: LOT-0000
6.1.2.
Informations sur les lauréats
Lauréat:
Nom officiel: Element Biosciences Netherlands B.V.
Offre:
Identifiant de l’offre: Tender Element Biosciences
Identifiant du lot ou groupe de lots: LOT-0000
Informations relatives au marché:
Identifiant du marché: Agreement with Element Biosciences
Date à laquelle le lauréat a été choisi: 01/04/2025
8. Organisations
8.1.
ORG-0001
Nom officiel: University of Helsinki
Numéro d’enregistrement: 0313471-7
Adresse postale: Fabianinkatu 33
Ville: Helsinki
Code postal: 00100
Subdivision pays (NUTS): Helsinki-Uusimaa (FI1B1)
Pays: Finlande
Point de contact: Hankinnat
Téléphone: +358 503188076
Rôles de cette organisation:
Acheteur
8.1.
ORG-0002
Nom officiel: Markkinaoikeus
Numéro d’enregistrement: 3006157-6
Adresse postale: Radanrakentajantie 5
Ville: Helsinki
Code postal: 00520
Subdivision pays (NUTS): Helsinki-Uusimaa (FI1B1)
Pays: Finlande
Téléphone: +358 295643300
Rôles de cette organisation:
Organisation chargée des procédures de recours
8.1.
ORG-0003
Nom officiel: Element Biosciences Netherlands B.V.
Numéro d’enregistrement: NL864563917B01
Adresse postale: Keizersgracht 391 A
Ville: Amsterdam
Code postal: 1016EJ
Subdivision pays (NUTS): Groot-Amsterdam (NL329)
Pays: Pays-Bas
Téléphone: +1 619 3530300
Rôles de cette organisation:
Soumissionnaire
Lauréat de ces lots: LOT-0000
8.1.
ORG-0004
Nom officiel: Hansel Oy (Hilma)
Numéro d’enregistrement: FI09880841
Adresse postale: Mannerheiminaukio 1a
Ville: Helsinki
Code postal: 00100
Subdivision pays (NUTS): Helsinki-Uusimaa (FI1B1)
Pays: Finlande
Point de contact: eSender
Téléphone: 029 55 636 30
Rôles de cette organisation:
TED eSender
Informations relatives à l’avis
Identifiant/version de l’avis: 46083360-2766-424a-af38-62e2f2634b6e - 01
Type de formulaire: Notification préalable d’attribution directe
Type d’avis: Avis en cas de transparence ex ante volontaire
Sous-type d’avis: 25
Date d’envoi de l’avis: 03/04/2025 09:55:35 (UTC) Western European Time, GMT
Date d’envoi de l’avis (eSender): 03/04/2025 09:55:49 (UTC) Western European Time, GMT
Langues dans lesquelles l’avis en question est officiellement disponible: anglais
Numéro de publication de l’avis: 218959-2025
Numéro de publication au JO S: 67/2025
Date de publication: 04/04/2025